Closed circuit heating and cooling systems must be well maintained to operate at optimum efficiency so it is essential that the correct water conditions are maintained at all times. This can be achieved using carefully selected inhibitors designed to control corrosion, scale/fouling and maintain flow and heat transfer. Our advanced KOOL LOOP closed circuit inhibitors have been scientifically formulated to protect closed systems including closed chilled water, low, medium and high temperature/pressure heating systems from the effects of both metallic corrosion and fouling all within in a single product. ChemREADY’s scale & corrosion inhibitors deliver improved performance, helping to reduce maintenance costs, improve reliability and optimize operational efficiency.
Request InfoProduct | Application Use | Industry Use |
---|---|---|
KOOL LOOP MN-602 | Recirculating, nonpotable hot and chill water systems utilizing soft water makeup |
KOOL LOOP MN-602 is a liquid scale and corrosion inhibitor designed for use in recirculating, nonpotable hot and chill water systems utilizing soft water makeup. A blend of corrosion inhibitors provides protection for steel, brass, bronze, copper and other metals commonly found in these types of water systems. A special inhibitor is also provided for protection of aluminum components. Scale inhibition is provided with a blend of synthetic polymer dispersants and calcium deposit control agents. |
KOOL LOOP LC | Low conductivity corrosion inhibitor in closed loop systems. |
KOOL LOOP LC is a liquid corrosion inhibitor designed for use in recirculating cooling and heating systems where a colorless, low conductivity, non polluting, non chromate formulation is required. A protective film is quickly established on copper materials which is tough enough to withstand system upsets. |
KOOL LOOP N-98 | Nitrite based corrosion inhibitor in closed loop systems. |
KOOL LOOP N-98 is liquid corrosion inhibitor designed for use in recirculating cooling and heating systems with aluminum heat exchangers. |
KOOL LOOP M-20 | Molybdate based corrosion inhibitor in closed loop systems. |
KOOL LOOP M-20 is a liquid corrosion inhibitor designed for use in recirculating cooling and heating systems where a colorless–non polluting–non chromate formulation is required. A protective film is quickly established on both Ferrous and non-Ferrous materials which is tough enough to withstand system upsets. This product is also designed to reduce frictional losses in the piping and protect the seating area of pump seals. |
KOOL LOOP M-91 | Molybdate based corrosion inhibitor in closed loop systems. |
KOOL LOOP M-91 is a liquid corrosion inhibitor designed for use in recirculating cooling and heating systems where a colorless–non polluting–non chromate formulation is required. A protective film is quickly established on both Ferrous and non-Ferrous materials which is tough enough to withstand system upsets. This product is also designed to reduce frictional losses in the piping and protect the seating area of pump seals. |
KOOL LOOP N-92 | Nitrite based corrosion inhibitor in closed loop systems. |
KOOL LOOP 92 is a liquid corrosion inhibitor designed for use in recirculating cooling and heating systems where a colorless–non polluting–non chromate formulation is required. A protective film is quickly established on both ferrous and non-ferrous materials which is tough enough to withstand system upsets. |
KOOL LOOP N-94 | Nitrite based corrosion inhibitor in closed loop systems. |
KOOL LOOP 94 is a liquid corrosion inhibitor designed for use in recirculating cooling and heating systems where a colorless–non polluting–non chromate formulation is required. A protective film is quickly established on both ferrous and non-ferrous materials which is tough enough to withstand system upsets. |
KOOL LOOP N-600 | Nitrite based corrosion inhibitor in closed loop systems. |
KOOL LOOP N-600 is a liquid corrosion inhibitor designed for use in recirculating cooling and heating systems where a colorless–non polluting–non chromate formulation is required. A protective film is quickly established on both ferrous and non-ferrous materials which is tough enough to withstand system upsets. |
KOOL LOOP Y-3024 | Closed loop treatment. |
Cleaner used in new construction – piping flush |