Water Facts Blog
Water Facts
Boiler Treatment Cooling Towers Legionella Water Treatment

An Overview Of Water Treatment Systems

A Brief Overview of Cooling Towers

Cooling towers are essential components of many industrial and commercial facilities. These systems use water to remove excess heat from air conditioning systems, refrigeration equipment, and other types of industrial machinery. However, the water used in cooling towers can become contaminated with bacteria, algae, and other impurities, which can lead to a variety of problems. To prevent these issues, many facilities use cooling tower treatment chemicals to keep their systems running smoothly and efficiently.

There are several types of chemicals that are commonly used in the treatment of cooling towers. These include biocides, scale inhibitors, corrosion inhibitors, and pH adjusters. Let’s take a closer look at each of these types of chemicals and how they can help to maintain the health and effectiveness of a cooling tower system.

Biocides are chemicals that are used to kill or inhibit the growth of bacteria, algae, and other microorganisms in the water used in cooling towers. These chemicals are often used in conjunction with other types of treatment chemicals to keep the water clean and free of contaminants. Some common biocides that are used in cooling tower treatment include chlorine, bromine, and quaternary ammonium compounds.

Scale inhibitors are chemicals that are used to prevent the formation of scale, which is a hard, crystalline deposit that can form on the surfaces of pipes and other equipment in a cooling tower system. Scale can reduce the efficiency of the system and cause serious problems if it is not properly controlled. Some common scale inhibitors that are used in cooling tower treatment include phosphonates, polymers, and acrylates.

Corrosion inhibitors are chemicals that are used to protect the metal surfaces of a cooling tower system from corrosion. These chemicals work by forming a protective film on the metal surfaces that helps to prevent the chemical reactions that can lead to corrosion. Some common corrosion inhibitors that are used in cooling tower treatment include amines, phosphates, and polymers.

pH adjusters are chemicals that are used to regulate the pH of the water in a cooling tower system. The pH of the water can affect the effectiveness of other treatment chemicals and can also contribute to the formation of scale and corrosion. Some common pH adjusters that are used in cooling tower treatment include acid, base, and buffer solutions.

It is important to use the appropriate treatment chemicals in a cooling tower system to ensure that it is running at peak efficiency and to prevent problems such as scale formation, corrosion, and biological growth. Proper treatment can also help to extend the life of the system and save money on maintenance and repairs. It is also important to follow the manufacturer’s instructions and safety precautions when using these chemicals to ensure their safe and effective use.

A Brief Overview of Legionella

Legionella is a type of bacteria that can cause a serious and potentially life-threatening form of pneumonia called Legionnaire’s disease. The bacteria are found naturally in water and can grow and multiply in systems such as cooling towers, hot water tanks, and large plumbing systems. When these systems are not properly maintained and disinfected, the bacteria can thrive and be spread through the air in the form of small droplets or mist.

People can contract Legionnaire’s disease by inhaling these contaminated droplets or mist. The disease can also be contracted by aspirating contaminated water into the lungs, although this is less common. People who are at a higher risk of contracting Legionnaire’s disease include those who are over 50 years old, smokers, heavy drinkers, and those with weakened immune systems or underlying health conditions.

Symptoms of Legionnaire’s disease include fever, chills, cough, shortness of breath, muscle aches, and headache. In severe cases, the disease can lead to respiratory failure, septic shock, and even death. The Centers for Disease Control and Prevention (CDC) estimates that between 8,000 and 18,000 people are hospitalized with Legionnaire’s disease in the United States each year.

There are several ways to prevent the growth and spread of Legionella bacteria in water systems. These include maintaining the proper temperature and pH of the water, regularly cleaning and disinfecting the system, and using chemicals such as chlorine or monochloramine to kill the bacteria. It is also important to regularly test the water for Legionella to ensure that it is not present in the system.

There are also several measures that can be taken to reduce the risk of contracting Legionnaire’s disease. These include avoiding inhaling mist or vapor from hot tubs, spas, and showers, and avoiding drinking water from sources that may be contaminated with the bacteria. It is also important to maintain good hygiene and to promptly seek medical attention if you develop symptoms of the disease.

There are several steps that facilities such as hotels, hospitals, and nursing homes can take to prevent the growth and spread of Legionella in their water systems. These include regularly maintaining and cleaning the systems, testing the water for the presence of the bacteria, and implementing appropriate disinfection protocols. It is also important for these facilities to have a plan in place to quickly and effectively respond to a Legionella outbreak to minimize the risk of transmission to guests or residents.

In addition to preventing the growth and spread of Legionella in water systems, it is also important to be aware of the potential for the bacteria to be present in other types of systems such as air conditioning units and humidifiers. These systems can also be sources of Legionella if they are not properly maintained and disinfected.

Overall, it is important to be aware of the potential risks associated with Legionella and to take steps to prevent the growth and spread of the bacteria in water systems. By following proper maintenance and disinfection protocols, facilities can protect their guests, residents, and employees from the serious and potentially life-threatening consequences of Legionnaire’s disease.

What To Know About Water Based Cooling Systems For Heating

Water-based cooling systems, also known as hydronic cooling systems, are a type of heating, ventilation, and air conditioning (HVAC) system that uses water to transfer heat from one location to another. These systems can be used to cool buildings by absorbing heat from the inside of the building and transferring it outside, or by absorbing heat from the outside air and transferring it inside.

There are several different types of water-based cooling systems, including:

  1. Closed-loop systems: These systems use a closed loop of water to transfer heat between the building and the outside environment. The water is pumped through a series of pipes, and heat is transferred to or from the water via a heat exchanger.
  2. Open-loop systems: These systems use a natural body of water, such as a river or lake, as the heat source or sink. Heat is transferred to or from the water via a heat exchanger.
  3. Evaporative cooling systems: These systems use the evaporation of water to cool the air. Hot, dry air is passed over a wet surface, such as a wet pad or mist, and the water evaporates, absorbing heat from the air in the process.

Water-based cooling systems have several advantages over other types of cooling systems. They are typically more energy efficient than air-based systems, as water has a higher thermal capacity than air and can more effectively transfer heat. They are also more durable and require less maintenance, as they do not have moving parts such as fans or compressors.

However, water-based cooling systems can be more complex to install and maintain than air-based systems, and they require a reliable source of water and a way to dispose of the wastewater. They also may not be suitable for climates with very low humidity, as the evaporative cooling process is less effective in dry air.

Overall, water-based cooling systems can be an effective and efficient way to cool buildings, but they may not be the best choice for every application. It is important to carefully consider the specific needs and constraints of a building and its location when deciding whether a water-based cooling system is the right choice.

A Quick View Of Boiler Maintenance Water Treatment Systems

  1. Regular inspections: Steam boilers should be inspected on a regular basis by a trained and qualified technician to ensure that they are operating safely and efficiently. These inspections should include a visual inspection of the boiler, as well as checks of the controls and safety devices.
  2. Cleaning: Boilers should be cleaned regularly to remove soot, scale, and other types of buildup that can reduce their efficiency and increase the risk of problems.
  3. Water treatment: The water used in a steam boiler should be treated to prevent the buildup of scale and corrosion. This can be done with chemicals or with a filtration system.
  4. Monitoring and adjusting water levels: The water level in a steam boiler should be monitored regularly to ensure that it is at the proper level. If the water level is too low, the boiler could run dry and be damaged, while a water level that is too high can cause problems with the pressure relief valve.
  5. Testing safety devices: The safety devices on a steam boiler, such as the pressure relief valve and low water cut-off, should be tested regularly to ensure that they are functioning properly.
  6. Checking and adjusting the burner: The burner on a steam boiler should be checked and adjusted as needed to ensure that it is operating efficiently and producing a clean, stable flame.
  7. Checking and adjusting the fuel supply: The fuel supply to a steam boiler should be checked and adjusted as needed to ensure that it is providing a consistent flow of fuel to the burner.
  8. Checking and adjusting the air supply: The air supply to a steam boiler should be checked and adjusted as needed to ensure that there is sufficient airflow for the burner to operate properly.
  9. Checking and adjusting the draft: The draft in a steam boiler should be checked and adjusted as needed to ensure that there is sufficient draft to remove flue gases from the boiler.
  10. Lubrication: The moving parts of a steam boiler, such as the pump and motor, should be lubricated regularly to ensure that they are operating smoothly and efficiently.

Where to Turn for Professional Cooling Tower Treatment and Advice

Talk to our experts at ChemREADY to ask us about risk assessments for your facility and available products suited and scaled for your water systems. We can help reduce the risk of corrosion and poor maintenence to avoid the consequences of damaged water treatment systems. Call ChemREADY today or contact us via our website.

Learn more about our Water Treatment Services and Chemical Products

Contact Us